Skip to main content
YONEIINNOVATIVE MATERIAL TECH

Materials engineering / Technical Q&A

Turn material questions into testable decisions

These answers summarize public parameters from YONEI application pages. Final selection still depends on the controlled TDS, color, thickness and project test plan.

Reviewed by YONEI R&D TeamLast reviewed:

In-depth technical articles

Engineering guides for material selection

Long-form technical guidance on polymer selection, electrical performance, thermoforming and additive systems.

Engineering questions

05

01

What do CTI 600V and UL PLC0 mean?

CTI is the comparative tracking index. UL PLC0 is the UL 746A performance level assigned to materials rated 600V or higher.

They describe resistance to tracking under contamination and electric stress, but do not replace terminal spacing, pollution-degree, housing design or end-product dielectric tests. PV connector programs should validate CTI, PLC, IP and the customer test plan together.

View application route
02

How is dual 85 different from HAST?

Dual 85 usually means 85°C / 85%RH steady-state aging; HAST accelerates moisture testing at higher temperature and saturated humidity.

Dual-85 1000H is often used for long-term hydrolysis comparison, while HAST 192h at 121°C / 100% RH provides a shorter accelerated route. The two cannot be converted directly and must be interpreted by grade, specimen, thickness and failure criteria.

View application route
03

When should V-0 or VTM-0 be specified?

V-0 applies to molded specimens; VTM-0 applies to thin films. The required construction and thickness determine the correct rating.

Injection-molded CCS brackets usually reference V-0, while PC films or insulation sheets may use VTM-0. Ratings must always be locked to thickness: V-0 at 1.2mm is not interchangeable with V-0 at 1.5mm.

View application route
04

Which data matter for CCS bracket materials?

Evaluate flame rating, heat, retained impact after dual 85, insulation, dimensional stability and molding window together.

Current public routes include CFR3010, CFR3051, CM9610 film and PA66+GF. Published data covers dual-85 1000H, V-0, HDT and impact, but project validation still depends on the actual part geometry and customer test plan.

View application route
05

How should PPO, PA66 and PPS be selected?

PPO favors low moisture and electrical stability, PA66 favors structural toughness and processing, and PPS favors high heat, rigidity and chemical resistance.

Outdoor connectors may use high-CTI F1-rated PPO; thin-wall charging guns may use halogen-free FR PA66+GF; hot or high-rigidity electrical structures may use PPS+GF. Impact, flame rating, appearance and cost remain part of the final decision.

View application route