Medical devices MEDICAL DEVICES

MEDICAL DEVICES

Cleanability, sterilization and reliable molding

Medical housings, injection pens and masks require a structured review of biocompatibility, sterilization, chemical resistance and optical clarity.

Recommended materials

Technical data

Request CM9610PF TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Class IIa

CM9610PF source direction

V-0

@1.5 mm

<0.1%

PPO water absorption

FDA

PX54F0HR data

Operating conditions

Four critical conditions for Medical devices

Each section follows the failure path for this application. Final targets depend on part design, wall thickness and the customer test plan.

01

steam / ETO

Sterilization

Reusable devices and housings need validation of heat, ETO and cleaning agents.

post-sterilization

02

ISO 10993

Biocompatibility

Contact duration and route determine the required biological tests.

ISO 10993

03

low defect

Clarity and appearance

Injection pens, masks and windows need clarity, low haze and stable color.

precision molding

04

low extraction

Chemical cleaning

Alcohols and disinfectants must not cause stress cracking or unacceptable extraction.

chemical resistance

Recommended materials

Recommended grades and data for Medical devices

Data is sourced from product pages and technical documents. The series, suffix, color and thickness must be locked in the controlled TDS.

FR route

CM9610PF

PFAS-free FR PC · FR medical-device housing

Flame
V-0 @1.5 mm
Regulation
PFAS/PTFE/bromine-free
Sterilization
autoclave direction
Compliance
RoHS / REACH / SCIP / UL

Technical data

Request CM9610PF TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Key data

FR route

CM9610PF

PFAS-free FR PC · FR medical-device housing

Flame
V-0 @1.5 mm
Regulation
PFAS/PTFE/bromine-free
Sterilization
autoclave direction
Compliance
RoHS / REACH / SCIP / UL

Product data identifies Class IIa medical and autoclave directions; verify the final color and biocompatibility report.

Technical data

Request CM9610PF TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Low-absorption option

PX54F0HR

Modified PPO / PPE · Control bays and precision medical structures

Flame
UL94 V-0
Water absorption
<0.1%
Certification
FDA / RoHS / REACH / ELV
Electrical
low dielectric loss

Medical devices are listed in the product page, but contact class and sterilization still require verification.

Technical data

Request PX54F0HR TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Project validation

CM2610

PC · Transparent, colorable medical platform

Base
polycarbonate
FR family
HB / V2
Appearance
natural, black, custom
Compliance
RoHS / REACH

A candidate PC platform; medical grade, ISO 10993 and sterilization claims require the matching suffix TDS.

Technical data

Request CM2610 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

CM9610PF · Source: content-inventory: CM9610PF product page

PX54F0HR · Source: content-inventory: PX54F0HR product page

CM2610 · Source: content-inventory: CM2610 product page

Validation & certification

Define contact classification before selecting a grade

Biocompatibility, sterilization cycles, cleaning agents and clarity are project inputs; 'medical grade' alone is insufficient.

01

ISO 10993

Biocompatibility

Select tests by contact duration and route.

02

Steam / ETO

Sterilization

Validate dimensions, color, mechanics and chemistry after cycling.

03

V-0 @1.5 mm

Flame

CM9610PF product direction; confirm by housing standard.

04

FDA / RoHS / REACH

Compliance

Match certificates and migration data to the final part.

ISO9001:2015IATF16949RoHSREACH

Public data and certificates do not replace project validation. Results apply only to the tested grade, color, thickness, specimen and conditions.

Technical data request

Request the controlled TDS for CM9610PF

Share the part, operating conditions and targets. A specialist will verify suffix, thickness, regulations and test conditions before sending the document.

Technical data

Request CM9610PF TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Application inquiry

Discuss Medical devices with our team

More complete inputs move the project faster into sample and validation work.

  • Device class and contact
  • Sterilization method and cycles
  • Clarity and color
  • Disinfectant exposure

Need general material guidance or company information?

Instant technical inquiry

Engineer available

YONEI