Skip to main content
YONEIINNOVATIVE MATERIAL TECH
Electronics & electrical ELECTRONICS & ELECTRICAL

ELECTRONICS & ELECTRICAL

High-CTI and high-rigidity engineering materials

Connectors, breakers and electrical housings must combine tracking resistance, heat, low absorption and thin-wall flame retardancy.

Recommended materials

Technical data

Request S265G8 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

600V

S265G8 CTI

265°C

HDT @1.8 MPa

200MPa

tensile strength

0.02%

24h water absorption

Operating conditions

Four critical conditions for Electronics & electrical

Each section follows the failure path for this application. Final targets depend on part design, wall thickness and the customer test plan.

01

CTI + dielectric stability

High-voltage tracking

Connectors and breakers need stable insulation under field, pollution and thermal stress.

CTI ≥600V

02

HDT + creep resistance

Heat and long-term load

Dense electronics near heat sources require rigidity and stable geometry.

HDT 265°C

03

low shrinkage + flow

Thin-wall molding

Connector walls need balanced fill, warpage, weld-line strength and tolerance.

shrinkage 0.2%

04

low absorption

Humidity

PPS and modified PPO provide stable insulation and dimensions in changing humidity.

0.02% / <0.1%

Recommended materials

Recommended grades and data for Electronics & electrical

Data is sourced from product pages and technical documents. The series, suffix, color and thickness must be locked in the controlled TDS.

High-CTI route

S265G8

PPS + 40%GF · Connectors, breakers and rigid structures

CTI
≥600V
Tensile
200 MPa
Flexural modulus
13,500 MPa
HDT
265°C @1.8 MPa

Technical data

Request S265G8 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Key data

High-CTI route

S265G8

PPS + 40%GF · Connectors, breakers and rigid structures

CTI
≥600V
Tensile
200 MPa
Flexural modulus
13,500 MPa
HDT
265°C @1.8 MPa
Water absorption
0.02% @24h
Flame
V-0 @1.6 / 3.2 mm

A black/custom high-rigidity PPS route for harsh electrical environments.

Technical data

Request S265G8 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Low-absorption option

PX54F0HR

Modified PPO / PPE · Connectors, 5G and precision electrical

Flame
UL94 V-0
Water absorption
<0.1%
Electrical
low dielectric loss
Process
injection / extrusion

Low absorption and dielectric stability suit high-speed connectors and communication structures.

Technical data

Request PX54F0HR TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

PFAS-free route

CM9610PF

PFAS-free FR PC · FR housings and internal brackets

Flame
V-0 @1.5 mm
System
halogen- and bromine-free char
Material
polycarbonate
Compliance
RoHS / REACH / SCIP / UL

For PFAS-free electronics housings and battery-side components, subject to project validation.

Technical data

Request CM9610PF TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

S265G8 · Source: content-inventory: S265G8 product page

PX54F0HR · Source: content-inventory: PX54F0HR product page

CM9610PF · Source: content-inventory: CM9610PF product page

Validation & certification

Validate electrical parts from material to assembly

CTI, HDT, water absorption, flame thickness and mechanics must all refer to a specific grade and specimen.

01

CTI ≥600V

Insulation

Published S265G8 data for high-CTI electrical structures.

02

HDT 265°C

Heat

At 1.8 MPa and 4 mm; melting point 285°C.

03

200 MPa

Mechanics

Tensile strength; flexural modulus 13,500 MPa.

04

1.6 / 3.2 mm

Flame

S265G8 V-0 data; validate against actual wall thickness.

ISO9001:2015IATF16949RoHSREACH

Public data and certificates do not replace project validation. Results apply only to the tested grade, color, thickness, specimen and conditions.

Technical data request

Request the controlled TDS for S265G8

Share the part, operating conditions and targets. A specialist will verify suffix, thickness, regulations and test conditions before sending the document.

Technical data

Request S265G8 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Application inquiry

Discuss Electronics & electrical with our team

More complete inputs move the project faster into sample and validation work.

  • Voltage and CTI target
  • Pitch and wall thickness
  • Continuous temperature
  • Flame and glow-wire requirement

Need general material guidance or company information?

Instant technical inquiry

Engineer available

YONEI

Hello, this is YONEI Innovative Material. What material solution do you need? Leave your requirement and contact details, and our engineer will reply as soon as possible.