SOLAR PV

High-CTI weathering PC for PV connectors

CM9610S-BK3A475 targets PV connectors with CTI 600V / UL PLC0, low-temperature ductility, F1 weathering and validated dual-85 performance.

Recommended materials

Technical data

Request CM9610S-BK3A475 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

600V

CTI / UL PLC0

1500H

dual-85 aging

-40°C

low-temperature ductility

V-0

@1.2 mm

Operating conditions

Four critical conditions for Solar PV components

Each section follows the failure path for this application. Final targets depend on part design, wall thickness and the customer test plan.

01

high CTI

Tracking risk

Outdoor moisture and contamination demand stable insulation and tracking resistance.

CTI 600V / PLC0

02

UV and F1

Outdoor weathering

PV components need long-term UV stability with retained mechanical and electrical performance.

F1

03

-40°C ductility

Cold installation

Cold-climate installation and impact require ductility below freezing.

-40°C

04

UL 94 V-0

Thin-wall FR

Compact connectors require flame retardancy at 1.2 mm.

V-0 @1.2 mm

Recommended materials

Recommended grades and data for Solar PV components

Data is sourced from product pages and technical documents. The series, suffix, color and thickness must be locked in the controlled TDS.

Primary route

CM9610S-BK3A475

High-performance FR PC · PV connector

CTI
600V / UL PLC0
Low temperature
-40°C ductility
Weathering
F1
Flame
V-0 @1.2 mm

Technical data

Request CM9610S-BK3A475 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Key data

Primary route

CM9610S-BK3A475

High-performance FR PC · PV connector

CTI
600V / UL PLC0
Low temperature
-40°C ductility
Weathering
F1
Flame
V-0 @1.2 mm
Dual 85
1500H
Sealing / IPT
1.5kV IP67

Designed for PV connectors; the published case reports more than 20% potential cost reduction versus PAGF/PPE routes.

Technical data

Request CM9610S-BK3A475 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Weathering option

PX54F0HR

Modified PPO / PPE · Connectors and 5G structures

Flame
UL94 V-0
Water absorption
<0.1%
Electrical
low dielectric loss
Compliance
RoHS / REACH / ELV / FDA

Low water absorption supports dimensional and dielectric stability in humid environments.

Technical data

Request PX54F0HR TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Hydrolysis option

CFR3010

FR PC/ABS · PV equipment structures

Flame
UL 94 V-0 direction
Dual 85
1000H
Impact after aging
above 10

The site article also identifies this dual-85 route for PV applications; revalidate for each housing.

Technical data

Request CFR3010 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

CM9610S-BK3A475 · Source: content-inventory: solar PV article

PX54F0HR · Source: content-inventory: PX54F0HR product page

CFR3010 · Source: content-inventory: CCS dual-85 article

Validation & certification

Validate electrical, environmental and flame performance together

A single flame rating does not cover PV reliability. CTI, cold ductility, UV, wet heat and sealing belong in one test plan.

01

CTI 600V

Tracking

UL PLC0 direction for the connector.

02

1500H

Wet heat

85°C / 85% RH performance retention.

03

1.5kV

Sealing / voltage

Published IP67 and IPT-related requirement.

04

F1

Weathering

UV and outdoor exposure stability.

ISO9001:2015IATF16949RoHSREACH

Public data and certificates do not replace project validation. Results apply only to the tested grade, color, thickness, specimen and conditions.

Technical data request

Request the controlled TDS for CM9610S-BK3A475

Share the part, operating conditions and targets. A specialist will verify suffix, thickness, regulations and test conditions before sending the document.

Technical data

Request CM9610S-BK3A475 TDS

Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Application inquiry

Discuss Solar PV components with our team

More complete inputs move the project faster into sample and validation work.

  • Connector geometry and wall
  • Voltage and CTI target
  • UV and wet-heat duration
  • Cold impact requirement

Need general material guidance or company information?

Instant technical inquiry

Engineer available

YONEI