Skip to main content
YONEIINNOVATIVE MATERIAL TECH
Solar PV components SOLAR PV

SOLAR PV

Solar PV Connector Materials for CTI 600V and dual-85 reliability

CM9610S-BK3A475 targets solar wire connector, solar cable MC4 connector and MC4 connector for solar panel applications with CTI 600V / UL PLC0, low-temperature ductility, F1 weathering and validated dual-85 performance.

Recommended materials

Technical data

Request CM9610S-BK3A475 TDS
Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

600V

CTI / UL PLC0

1500H

dual-85 aging

-40°C

low-temperature ductility

V-0

@1.2 mm

Operating conditions

Four critical conditions for Solar PV components

Each section follows the failure path for this application. Final targets depend on part design, wall thickness and the customer test plan.

Whether the project uses a solar wire connector, a solar cable MC4 connector or an MC4 connector for solar panel assemblies, material selection should be validated against CTI, dual-85 aging, UV exposure, low-temperature impact and thin-wall flame performance together.

01

high CTI

Tracking risk

Outdoor moisture and contamination demand stable insulation and tracking resistance.

CTI 600V / PLC0

02

UV and F1

Outdoor weathering

PV components need long-term UV stability with retained mechanical and electrical performance.

F1

03

-40°C ductility

Cold installation

Cold-climate installation and impact require ductility below freezing.

-40°C

04

UL 94 V-0

Thin-wall FR

Compact connectors require flame retardancy at 1.2 mm.

V-0 @1.2 mm

Recommended materials

Recommended grades and data for Solar PV components

Data is sourced from product pages and technical documents. The series, suffix, color and thickness must be locked in the controlled TDS.

Primary route

CM9610S-BK3A475

High-performance FR PC · PV connector

CTI
600V / UL PLC0
Low temperature
-40°C ductility
Weathering
F1
Flame
V-0 @1.2 mm

Technical data

Request CM9610S-BK3A475 TDS
Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Key data

Primary route

CM9610S-BK3A475

High-performance FR PC · PV connector

CTI
600V / UL PLC0
Low temperature
-40°C ductility
Weathering
F1
Flame
V-0 @1.2 mm
Dual 85
1500H
Sealing / IPT
1.5kV IP67

Designed as a Drop-in Solution for PV connectors; the published case reports more than 20% potential material cost reduction, subject to joint validation.

Technical data

Request CM9610S-BK3A475 TDS
Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Weathering option

PX54F0HR

Modified PPO / PPE · Connectors and 5G structures

Flame
UL94 V-0
Water absorption
<0.1%
Electrical
low dielectric loss
Compliance
RoHS / REACH / ELV / FDA

Low water absorption supports dimensional and dielectric stability in humid environments.

Technical data

Request PX54F0HR TDS
Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Hydrolysis option

CFR3010

FR PC/ABS · PV equipment structures

Flame
UL 94 V-0 direction
Dual 85
1000H
Impact after aging
above 10

The site article also identifies this dual-85 route for PV applications; revalidate for each housing.

Technical data

Request CFR3010 TDS
Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

CM9610S-BK3A475 · Source: content-inventory: solar PV article

PX54F0HR · Source: content-inventory: PX54F0HR product page

CFR3010 · Source: content-inventory: CCS dual-85 article

Learn more about the difference between MC4 and SAE connectors in our technical guide.

For a deeper explanation of test methods and PLC levels, read our CTI 600V selection guide before finalizing the connector material.

Technical review statement

Technical parameters on this page are reviewed by the YONEI R&D Center. The controlled TDS is the final reference.

Reviewed by YONEI R&D Team ·

Validation & certification

Validate electrical, environmental and flame performance together

A single flame rating does not cover PV reliability. CTI, cold ductility, UV, wet heat and sealing belong in one test plan.

01

CTI 600V

Tracking

UL PLC0 direction for the connector.

02

1500H

Wet heat

85°C / 85% RH performance retention.

03

1.5kV

Sealing / voltage

Published IP67 and IPT-related requirement.

04

F1

Weathering

UV and outdoor exposure stability.

ISO9001:2015IATF16949RoHSREACH

Public data and certificates do not replace project validation. Results apply only to the tested grade, color, thickness, specimen and conditions.

Technical data request

Request the controlled TDS for CM9610S-BK3A475

Share the part, operating conditions and targets. A specialist will verify suffix, thickness, regulations and test conditions before sending the document.

Technical data

Request CM9610S-BK3A475 TDS
Your details are used only to send technical information relevant to this application. Values are typical and require project validation.

Application inquiry

Discuss Solar PV components with our team

More complete inputs move the project faster into sample and validation work.

  • Connector geometry and wall
  • Voltage and CTI target
  • UV and wet-heat duration
  • Cold impact requirement

Need general material guidance or company information?

De-identified case library / Production validation

Validated by Real-World Applications

See how real operating conditions translate into material selection and validation paths across solar, charging and smart cleaning.

View de-identified case studies

Solar connector technical FAQ

Engineering questions before material selection

Interface standards, tracking resistance and wet-heat durability should be reviewed as one material validation plan.

01What is the difference between SAE and MC4 solar connectors?
SAE connectors are commonly used as two-pin latching connectors in off-grid, RV and portable solar systems. MC4 is a standardized family of photovoltaic module connectors with locking contacts and dedicated sealing systems. They are not interchangeable, and mixed-brand MC4 products should only be mated after the manufacturer confirms intermateability. From a material perspective, both connector types require stable insulation, low water absorption and long-term resistance to UV, thermal cycling and hydrolysis.
02Why is CTI 600V important for solar PV connectors?
Comparative Tracking Index measures how well an insulating material resists carbonized leakage paths under moisture and contamination. A CTI of 600 V can support a higher electrical safety margin in compact, high-voltage PV connectors, but the result is only valid for the tested grade, color, thickness and specimen geometry. The material should be reviewed together with pollution degree, creepage and clearance requirements, rather than using CTI as a stand-alone approval.
03How do PA66 GF25 materials perform in double 85 tests?
PA66 GF25 provides useful stiffness and dimensional stability for connector housings, but standard PA66 can lose mechanical performance under prolonged 85°C / 85% RH exposure. A connector-oriented grade should use a heat-stabilized, hydrolysis-resistant formulation. The validation report should compare key properties before and after aging—such as tensile strength, impact strength, appearance, weight change and electrical performance—rather than reporting only a pass/fail result. Acceptance criteria should be fixed against the actual 1000 h or 1500 h project requirement.

Instant technical inquiry

Engineer available

YONEI

Hello, this is YONEI Innovative Material. What material solution do you need? Leave your requirement and contact details, and our engineer will reply as soon as possible.