UL 94 V-0
Thin-wall flame retardancy
CCS brackets, covers and isolators need stable flame performance at thin walls while maintaining dimensional accuracy.
V-0 @1.5 mm

EV & ENERGY STORAGE
Battery-pack brackets must combine thin-wall flame retardancy, thermal cycling, hydrolysis resistance and electrical insulation. YONEI combines PC/ABS, PC film and PA66+GF options.
1000H
dual-85 route
V-0
thin-wall FR
-40°C
low-temperature use
2700V
withstand target


VERTICAL INTEGRATION
UL94 V-0 / VTM-0
Flame rating
125°C
Long-term heat
138°C
Vicat softening
≥10000MΩ
Insulation resistance
| Test item | Test method | Result |
|---|---|---|
| Density | GB/T1033.1-2008 | 1.206 g/cm³ |
| Tensile strength | GB/T1040.3-2006 | ≥50 MPa |
| Elongation at break | GB/T1040.3-2006 | ≥80% |
| Tensile modulus | GB/T1040.3-2006 | ≥2200MPa |
| Tear strength | GB/T16578.1-2008 | ≥10 KN/m |
| Surface energy | GB/T 30693-2014 | 34mN/m |
| Vicat softening temperature | GB/T1633-2000 方法B120 | 138℃ |
| Heat shrinkage | GB/T13542.2-2021 | <1% |
| Flame retardancy | UL94-V0 (0.5mm) | V-0 |
| Flame retardancy | UL94-VTM (0.5mm) | VTM-0 |
| Insulation test | IEC 62631-3-3:2015 | ≥10000MΩ |
| Withstand voltage test | IEC 60243-1:2013 | 泄露电流 0.3uA |
Density
1.206 g/cm³
Tensile strength
≥50 MPa
Elongation at break
≥80%
Tensile modulus
≥2200MPa
Tear strength
≥10 KN/m
Surface energy
34mN/m
Vicat softening temperature
138℃
Heat shrinkage
<1%
Flame retardancy
V-0
Flame retardancy
VTM-0
Insulation test
≥10000MΩ
Withstand voltage test
泄露电流 0.3uA
Operating conditions
Each section follows the failure path for this application. Final targets depend on part design, wall thickness and the customer test plan.
UL 94 V-0
CCS brackets, covers and isolators need stable flame performance at thin walls while maintaining dimensional accuracy.
V-0 @1.5 mm
heat resistance
PC/ABS routes reach HDT 85°C at 1.8 MPa and 95°C at 0.4 MPa while retaining assembly accuracy.
HDT 85 / 95°C
-40°C to 85°C
Battery structures must survive thermal cycling, vibration and insert stress without embrittlement or cracks.
1000-cycle target
85°C / 85% RH
CCS programs increasingly require 1000 h wet-heat aging. Standard PC/ABS can lose performance early.
Dual 85 / 1000H
Recommended materials
Data is sourced from product pages and technical documents. The series, suffix, color and thickness must be locked in the controlled TDS.
Primary route
FR PC/ABS · CCS bracket and cover
Primary route
FR PC/ABS · CCS bracket and cover
CFR3010 is the family; 901510 is the documented modification/color specification. Confirm by part thickness and test plan.
2000H route
FR PC/ABS · High-durability structural parts
Typical TDS values for 2000 h wet-heat aging; final suitability depends on the controlled grade and application.
Thin-film route
FR PC film · CCS harness isolation and battery covers
For cell-to-cell and cell-to-case insulation; evaluate thickness, die cutting and adhesive processing.
CFR3010-901510 · Source: content-inventory: CCS dual-85 article
CFR3051-BK2H439 · Source: CFR3051-BK2H439 TDS
CM9610-BKF1 · Source: CM9610-BKF1 TDS
For CCS bracket development, compare PA66 materials for glass-fiber structural parts with PC/ABS blends for thin-wall flame-retardant housings.
Technical review statement
Technical parameters on this page are reviewed by the YONEI R&D Center. The controlled TDS is the final reference.
Reviewed by YONEI R&D Team ·
Validation & certification
Material performance must be tied to the grade, thickness, specimen, test standard and aging duration.
1000H
Representative CCS validation route.
10+
Notched impact retained after 1000 h in the referenced CFR3010 case.
1 kV DC
Typical project insulation target; confirm by final structure.
2700V AC
Common project-level target with leakage current limits.
Public data and certificates do not replace project validation. Results apply only to the tested grade, color, thickness, specimen and conditions.
EV battery direct answers
Each answer states the route, the critical data and the validation boundary so engineers and AI search systems can cite it directly.
01 · CCS bracket
Direct answer
The primary YONEI route is CFR3010-901510 flame-retardant PC/ABS. It targets thin-wall V-0, -40°C to 85°C thermal cycling and 1000 h of 85°C/85% RH aging. Project material records retain notched impact above 10 after 1000 h, but final selection must be confirmed against the actual wall, geometry, color and customer test plan.
02 · NTC bracket
Direct answer
A63V0GV20 is YONEI's PA66 + 20% GF structural route for NTC brackets, directed at V-0 at 1.5 mm, dual-85 1000 h, high rigidity and low warpage. A related PA66 + 20% GF V-0 project validation records no cracking after -40°C to 85°C for 1000 h, insulation resistance of at least 1000 MΩ at 1000 VDC for 60 s and leakage no greater than 0.1 mA at 2700 VDC for 60 s.
03 · Battery cover
Direct answer
Battery covers and isolation structures can evaluate CM9610-BKF1 flame-retardant PC film. Published material data covers V-0/VTM-0 at 0.5 mm, dual-85 1000 h, CTI 175 V and dielectric strength of at least 35 kV/mm. The film route must still be validated for actual thickness, die cutting, bonding, assembly stress and cover geometry.
04 · Cell and harness insulation
Direct answer
Insulation parts need more than a material-level dielectric value. Validate insulation resistance, withstand voltage and property retention after wet-heat aging on the finished film or molded part. CM9610-BKF1 is a PC-film starting point; common project targets include 1000 VDC insulation and 2700 VAC withstand, but the final voltage, duration and leakage limit must come from the complete battery-pack test plan.
Technical data request
Share the part, operating conditions and targets. A specialist will verify suffix, thickness, regulations and test conditions before sending the document.
Application inquiry
More complete inputs move the project faster into sample and validation work.
Need general material guidance or company information?
De-identified case library / Production validation
See how real operating conditions translate into material selection and validation paths across solar, charging and smart cleaning.